Login | Register

A Generalized Radiosity Simulation Model and Full-Scale Experimental Verification of a Corner Office having Three Section Façade with Motorized Shading

Title:

A Generalized Radiosity Simulation Model and Full-Scale Experimental Verification of a Corner Office having Three Section Façade with Motorized Shading

Hossain, Shahriar (2016) A Generalized Radiosity Simulation Model and Full-Scale Experimental Verification of a Corner Office having Three Section Façade with Motorized Shading. Masters thesis, Concordia University.

[thumbnail of Hossain_MASc_F2016.pdf]
Preview
Text (application/pdf)
Hossain_MASc_F2016.pdf - Accepted Version
2MB

Abstract

Daylight distribution models are essential for daylighting design and present information in a visual manner that facilitates decision making. With an accurate model, daylight in a space can be distributed in an efficient and comfortable way, so that the need for electric lighting in daytime is reduced. On the other hand, motorized shades can be controlled automatically to better distribute daylight on the work plane and reduce or avoid glare.
Most of modern buildings, both commercial and high-rise residential, have windows in more than one orientation and have the provision for daylight penetration into space. In this study, a radiosity model for simulating the daylight distribution of a corner office having two windows in various orientations with motorized shades has been developed. The model calculates the illuminance at different locations on the work plane.
The simulation model based on radiosity theory is verified with measured data under overcast and clear sky conditions with direct and diffuse lighting, and a parametric analysis is carried out for various room shapes and shading devices and façade orientations. The model is implemented in Mathcad and used to predict the illuminance distribution in the room for developing improved control strategies for shade positions and also for design guidelines to select the properties of the shades. Three section façade is considered with the bottom section being opaque (spandrel), the middle viewing section and a top daylighting section. Variable shade transmittance in the middle and top section of the facades is studied, and it is shown that having a higher transmittance in the top section results in improved daylight utilization and a middle section with lower transmittance provide privacy to the building occupants. Specific recommendations are made for shade transmittances for upper and middle part of the façade to maintain occupant privacy with acceptable illuminance in the work-plane.

Divisions:Concordia University > Gina Cody School of Engineering and Computer Science > Building, Civil and Environmental Engineering
Item Type:Thesis (Masters)
Authors:Hossain, Shahriar
Institution:Concordia University
Degree Name:M.A. Sc.
Program:Building Engineering
Date:September 2016
Thesis Supervisor(s):Athienitis, Andreas
Keywords:Radisity Model corner office
ID Code:981883
Deposited By: SHAHRIAR HOSSAIN
Deposited On:08 Nov 2016 14:04
Last Modified:18 Jan 2018 17:54

References:

1. Energy Use Data Handbook 2009-2013, Natural Resources Canada.
2. Athienitis, A. (1999). Building Tharmal Analysis. Boston, U.S.A., Mathsoft Inc.
3. Athienitis, A. and W. O'Brien (2015). Modeling, Design, and Optimization of Net-Zero Energy Buildings, Ernst & Sohn.
4. Athienitis, A. K. and U. Boxer (2001). Effect of numerical model detail on prediction of interior illumination levels. Canadian Congress of Applied Mechanics. Monteal, QC.
5. Athienitis, A. K. and M. Santamouris (2002). Thermal Analysis and Design of Passive Solar Buildings, James & James.
6. Athienitis, A. K. and A. Tzempelikos (2002). "A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device." Solar Energy 72(4): 271-281.
7. Bellia, L., et al. (2014). "Overview on Solar Shading Systems for Buildings." Energy Procedia 62: 309-317.
8. Boyce, P., et al. (2003). The Benefits of Daylight Through Windows. Troy, New York, Lighting Research Center, Rensselaer Polytechnic Institute.
9. Chan, Y.-C. and A. Tzempelikos (2012). A Hybrid Ray-Racing and Radiosity Method for Calculating Radiation Transport and Illuminance Distribution in Spaces With Venetian Blinds. International High Performance Buildings Conference. Purdue,: 3220 (3221-3210).
10. Escuyer, S. and M. Fontoynont (2001). "Lighting controls: a field study of office workers’ reactions." Lighting Research and Technology 33(2): 77-94.
11. Farley, K. M. J. and J. A. Veitch (2001). A Room With A View: A Review of the Effects of Windows on Work and Well-Being. Research Report, NRC Institute for Research in Construction; 136.
12. Glassner, A. S., Ed. (1989). An introduction to ray tracing. London, UK, Academic Press Ltd.
13. Heschong, L., et al. (2002). "Daylighting Impacts on Human Performance in School." Journal of the Illuminating Engineering Society 31(2): 101-114.
14. Kapsis, K. (2009). Modeling, Control & Performance Evaluation of Bottom‐up Motorized Shade. Building, Civil, and Environmental Engineering. Montreal, Quebec, Canada, Concordia University. Master of Applied Science.
15. Kapsis, K. and A. K. Athienitis (2015). "A study of the potential benefits of semi-transparent photovoltaics in commercial buildings." Solar Energy 115: 120-132.
16. Kapsis, K., et al. (2015). "Daylight Performance of Perimeter Office Façades utilizing Semi-transparent Photovoltaic Windows: A Simulation Study." 6th International Building Physics Conference, IBPC 2015 78: 334-339.
17. Kapsis, K., et al. (2010). "Daylighting performance evaluation of a bottom-up motorized roller shade." Solar Energy 84(12): 2120-2131.
18. Kuhn, T. E., et al. (2001). "Evaluation of overheating protection with sun-shading systems." Solar Energy 69, Supplement 6: 59-74.
19. Lee, E. S., et al. (1998). "Thermal and daylighting performance of an automated venetian blind and lighting system in a full-scale private office." Energy and Buildings 29(1): 47-63.
20. Lehar, M. A. and L. R. Glicksman (2007). "Rapid algorithm for modeling daylight distributions in office buildings." Building and Environment 42(8): 2908-2919.
21. Mettanant, V. and P. Chaiwiwatworakul (2014). "Automated Vertical Blinds for Daylighting in Tropical Region." Energy Procedia 52: 278-286.
22. Mills, L. R. and W. R. McCluney (1993). "The benefits of using window shades." ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers) 35:11: 20-27.
23. Morini, G. L., et al. (2014). "Internal Versus External Shading Devices Performance in Office Buildings." Energy Procedia 45: 463-472.
24. Mukherjee, S., et al. (2010). "Closed Loop Integrated Lighting and Daylighting Control for Low Energy Buildings." ACEEE Summer Study on Energy Efficiency in Buildings 9: 252-269.
25. Muller, S., et al. (1995). A radiosity approach for the simulation of daylight. Rendering Techniques. Dublin, Ireland: 12-14.
26. Murdoch, J. B. (2003). Illuminating Engineering: From Edison's Lamp to the LED, Visions Communications.
27. Perez, R., et al. (1990). "Modeling daylight availability and irradiance components from direct and global irradiance." Solar Energy 44(271-289).
28. Reinhart, C. F. and K. Voss (2003). "Monitoring manual control of electric lighting and blinds." Lighting Research and Technology 35(3): 243-258.
29. Robinson, D. and A. Stone (2006). "Internal illumination prediction based on a simplified radiosity algorithm." Solar Energy 80(3): 260-267.
30. Shen, E., et al. (2014). "Energy and visual comfort analysis of lighting and daylight control strategies." Building and Environment 78: 155-170.
31. Shen, H. and A. Tzempelikos (2014). A Global Method for Efficient Synchronized Shading Control Using the “Effective daylight” Concept. 3rd International High Performance Buildings Conference. Purdue.
32. Skelly, M. J. and M. A. Wilkinson (2001). "The evolution of interactive facades: improving automated blind control." Whole life performance of facades: 129-142.
33. Tzempelikos, A., et al. (2007). Daylight and luminaire control in a perimeter zone using an automated venetian blind. 28th AIVC Conference on Building Low Energy Cooling and Advanced Ventilation Technologies in the 21st Century. Crete island, Greece.
34. Vine, E., et al. (1998). "Office worker response to an automated Venetian blind and electric lighting system: a pilot study." Energy and Buildings 28(2): 205-218.
35. Wienold, J. and J. Christoffersen (2006). "Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras." Energy and Buildings 38(7): 743-757.
All items in Spectrum are protected by copyright, with all rights reserved. The use of items is governed by Spectrum's terms of access.

Repository Staff Only: item control page

Downloads per month over past year

Research related to the current document (at the CORE website)
- Research related to the current document (at the CORE website)
Back to top Back to top