Field Measurements of Wind-Driven Rain on Mid - and High - Rise Buildings in Two Canadian Regions

Title:

Field Measurements of Wind-Driven Rain on Mid - and High - Rise Buildings in Two Canadian Regions

Deb Nath, Uzzwal Kumar (2015) Field Measurements of Wind-Driven Rain on Mid - and High - Rise Buildings in Two Canadian Regions. Masters thesis, Concordia University.

[thumbnail of Deb Nath_MASc_S2016.pdf]
Preview
Text (application/pdf)
Deb Nath_MASc_S2016.pdf - Accepted Version
10MB

Abstract

Wind-driven rain (WDR) is an important boundary condition for the study of the hygrothermal behaviour and durability of building envelopes. Understanding the WDR characteristics is important for establishing designs that minimize the moisture related issues. The objectives of this study are to generate a unique set of measurements to characterize the WDR distribution on mid- and high-rise buildings for different Canadian climatic regions, to provide data for validating CFD models and to evaluate the accuracy of existing semi-empirical methods used for quantifying WDR loads on building façades. Three buildings located in two Canadian cities (i.e., McLeod House in Fredericton; HB and FB Building in Montreal) have been instrumented with equipment to simultaneously record local weather data of wind speed, wind direction, temperature, relative humidity, horizontal rainfall, and WDR loads on building façades. Onsite data, collected for fourteen months from McLeod House, fifteen months from HB Building, and twelve months from FB Building, has been used for analysis. The historical and onsite wind and rain conditions, spatial distribution of wind-driven rain on façades in terms of catch ratios and wall factors, and comparisons between measured and predicted wind-driven rain using the semi-empirical models are reported for the monitoring periods.

The analysis of field measurements shows that catch ratios vary with rain events with higher values at the corners and edges of the façades. Typically catch ratios are higher at the top of the facades and decrease towards the bottom. The catch ratios are higher for the thirteen story high-rise building compared to the four and seven story mid-rise buildings at the same height below the roofline. Catch ratios are higher when approaching wind is normal to the façade and values increase with the increase of wind speed. Discrepancies between the ISO standard suggested wall factors and wall factors calculated based on measurements are observed for all three test buildings. It is found that the wall factors vary along both the building height and across the building width, while the ISO standard only suggests two values along the building height with no change across the building width. The ISO semi-empirical model overestimates the WDR at all monitored façade locations on McLeod House and HB Building, and 83% of the monitored façade locations on FB Building. The ASHRAE 160 model overestimates the WDR amount largely for most of the monitored façade locations of the test buildings. The discrepancies between measurements and predictions using semi-empirical models are due to the lack of variation of wall factors across building façade suggested in the standards and limited number of building geometries. The errors associated with WDR measurements vary with rain events with the maximum error contributed by adhesion-water-evaporation, however, the total amount of error is small as compared to WDR amount. To improve the semi-empirical models for estimating WDR on façade, wall factors based on field measurements on buildings with a wider range of building geometries and at more façade locations are needed.

Divisions:Concordia University > Gina Cody School of Engineering and Computer Science > Building, Civil and Environmental Engineering
Item Type:Thesis (Masters)
Authors:Deb Nath, Uzzwal Kumar
Institution:Concordia University
Degree Name:M.A. Sc.
Program:Building Engineering
Date:10 December 2015
Thesis Supervisor(s):Ge, Hua
ID Code:980732
Deposited By: UZZWAL KUMAR DEB NATH
Deposited On:09 Jun 2016 15:11
Last Modified:18 Jan 2018 17:51

References:

REFERENCES

Abuku, M., Blocken, B., Carmeliet, J., & Roels, S. (2006). A status report of wind-driven rain research at the laboratory of building physics, KU Leuven. Proceedings of the Fourth International Symposium on Computational Wind Engineering,
Abuku, M., Blocken, B., Nore, K., Thue, J. V., Carmeliet, J., & Roels, S. (2009). On the validity of numerical wind-driven rain simulation on a rectangular low-rise building under various oblique winds. Building and Environment, 44(3), 621-632.
Abuku, M., Janssen, H., Blocken, B., Carmeliet, J., & Roels, S. (2006). Wind-driven rain load on building enclosures–towards the reliable prediction of absorption and evaporation. IEA Annex 41 Whole Building Heat, Air and Moisture Response, Subtask 3-Boundary Condition,
Abuku, M., Janssen, H., & Roels, S. (2009). An onset to whole building hygrothermal modelling under wind-driven rain loads. Building Simulation 2009: 11th International Building Performance Simulation Association Conference and Exhibition,
Abuku, M., Blocken, B., & Roels, S. (2009). Field measurement and numerical analysis of wind-driven rain absorption and evaporation on building facades.
ASHRAE 2009. ASHRAE standard 160-criteria for moisture control design analysis in buildings. AHSRAE, Atlanta, USA.
Baheru, T., Chowdhury, A. G., Bitsuamlak, G., & Tokay, A. (2013). A parametric representation of wind-driven rain in experimental setups. Advances in Hurricane Engineering@ sLearning from our Past, 270-282.
Baheru, T., Chowdhury, A. G., Pinelli, J., & Bitsuamlak, G. (2014). Distribution of wind-driven rain deposition on low-rise buildings: Direct impinging raindrops versus surface runoff. Journal of Wind Engineering and Industrial Aerodynamics, 133, 27-38.
Blocken, B.J.E. & Carmeliet, J.E. (2005). Guidelines for wind, rain and wind-driven rain measurements at test-building sites. Proceedings of the 7th Symposium on Building Physics in the Nordic Countries: Reykjavik, pp 530-537.
Blocken, B., Abuku, M., Roels, S., & Carmeliet, J. (2009). Wind-driven rain on building facades: Some perspectives. EACWE, 5, 19-23.
Blocken, B., Briggen, P., Schellena, H., & Carmelietb, J. (2010). Intercomparison of wind-driven rain models based on a case study with full-scale measurements.
Blocken, B., & Carmeliet, J. (2000a). Driving rain on building envelopes-I. numerical estimation and full-scale experimental verification. Journal of Building Physics, 24(1), 61-85.
Blocken, B., & Carmeliet, J. (2000b). Driving rain on building envelopes—II. representative experimental data for driving rain estimation. Journal of Building Physics, 24(2), 89-110.
Blocken, B., & Carmeliet, J. (2002). Spatial and temporal distribution of driving rain on a low-rise building. Wind and Structures, 5(5), 441-462.
Blocken, B., & Carmeliet, J. (2004). A simplified approach for quantifying driving rain on buildings. Proc.of Performance of Exterior Envelopes of Whole Buildings IX, Clearwater,
Blocken, B., & Carmeliet, J. (2005). High-resolution wind-driven rain measurements on a low-rise building—experimental data for model development and model validation. Journal of Wind Engineering and Industrial Aerodynamics, 93(12), 905-928.
Blocken, B., & Carmeliet, J. (2006). The influence of the wind-blocking effect by a building on its wind-driven rain exposure. Journal of Wind Engineering and Industrial Aerodynamics, 94(2), 101-127.
Blocken, B., & Carmeliet, J. (2007). On the errors associated with the use of hourly data in wind-driven rain calculations on building facades. Atmospheric Environment, 41(11), 2335-2343.
Blocken, B., & Carmeliet, J. (2010). Overview of three state-of-the-art wind-driven rain assessment models and comparison based on model theory. Building and Environment, 45(3), 691-703.
Blocken, B., & Carmeliet, J. (2008). Guidelines for the required time resolution of meteorological input data for wind-driven rain calculations on buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96(5), 621.
Blocken, B., & Carmeliet, J. (2012). A simplified numerical model for rainwater runoff on building facades: Possibilities and limitations. Building and Environment, 53, 59.
Blocken, B., Derome, D., & Carmeliet, J. (2013). Rainwater runoff from building facades: A review. Building and Environment, 60, 339.
Blocken, B., Dezso, G., van Beeck, J., & Carmeliet, J. (2010). Comparison of calculation models for wind-driven rain deposition on building facades. Atmospheric Environment, 44(14), 1714.
Blocken, B., & Carmeliet, J. (2004). A review of wind-driven rain research in building science. Journal of Wind Engineering and Industrial Aerodynamics, 92(13), 1079.
Blocken, B., & Carmeliet, J. (2006). On the accuracy of wind-driven rain measurements on buildings. Building and Environment, 41(12), 1798.
Blocken, B., & Carmeliet, J. (2007). Validation of CFD simulations of wind-driven rain on a low-rise building facade. Building and Environment, 42(7), 2530.
Campbell Scientific (Canada) Corp. (2003). Instruction manual: Metetorological instruments- multi-plate radiation shield. In Campbell Scientific (Canada) corp. (Ed.), (pp. 1-8)
Campbell Scientific (Canada) Corp. (2013). Instruction manual: TE525 tipping bucket rain gage. In Campbell Scientific (Canada) Corp. (Ed.), (pp. 1-14)
Campbell Scientific (Canada) Corp. (June 2013a). Instruction manual: 05103, 05103-45, 05106, and 05305 R.M. young wind monitors. In Campbell Scientific (Canada) Corp. (Ed.), (pp. 1-16)
Campbell Scientific (Canada) Corp. (June 2013b). Instruction manual: HC2-S3-L temperature and relative humidity probes. In Campbell Scientific (Canada) Corp. (Ed.), (pp. 4-18)
Chand, I., & Bhargava, P. (2002). Estimation of driving rain index for India. Building and Environment, 37(5), 549-554.
Choi, E. (1993). Velocity and impact direction of WDR on building facade. (). Singapore 2263: School of Civil and Structural Engineering, Nanyang Technological University.
Choi, E. C. (1994). Parameters affecting the intensity of wind-driven rain on the front face of a building. Journal of Wind Engineering and Industrial Aerodynamics, 53(1), 1-17.
Choi, E. C. (1999). Wind-driven rain on building faces and the driving-rain index. Journal of Wind Engineering and Industrial Aerodynamics, 79(1), 105-122.
Choi, E. C. (2000). Variation of wind-driven rain intensity with building orientation. Journal of Architectural Engineering, 6(4), 122-128.
Choi, E. C. C. (1994). Determination of wind-driven-rain intensity on building faces. Journal of Wind Engineering and Industrial Aerodynamics, 51(1), 55.
Coutu, S., Wyrsch, V., Rossi, L., Emery, P., Golay, F., & Carneiro, C. (2013). Modelling wind-driven rain on buildings in urbanized area using 3-D GIS and LiDAR datasets. Building and Environment, 59, 528-535.
Environment canada. (2015). Retrieved from http://www.climate.weather.gc.ca/advanceSearch/searchHistoricData_e.html#stnNameTab
Erkal, A., D’Ayala, D., & Sequeira, L. (2012). Assessment of wind-driven rain impact, related surface erosion and surface strength reduction of historic building materials. Building and Environment, 57, 336-348.
Ge, H. (2015). Influence of time resolution and averaging techniques of meteorological data on the estimation of wind-driven rain load on building facades for canadian climates. Journal of Wind Engineering and Industrial Aerodynamics, 143, 50-61. doi:http://dx.doi.org/10.1016/j.jweia.2015.04.019
Ge, H., & Krpan, R. (2009). Wind-driven rain study in the coastal climate of British Columbia. ( No. Final Report). BC, Canada: Submitted to: Canada Mortgage and Housing Corporation.
Ge, H., & Krpan, R. (2007). Field measurement of wind-driven rain on a low-rise building in the coastal climate of British Columbia. Proceedings of the 11 Th Canadian Conference on Building Science and Technology, March, Banff,
Giarma, C., & Aravantinos, D. (2014). On building components' exposure to driving rain in Greece. Journal of Wind Engineering and Industrial Aerodynamics, 125, 133-145.
Google maps. (2015a). Retrieved from https://www.google.com/maps/d/edit?mid=z9TttLVWPjlY.kGZjZ2WKAPc4&hl=en
Google maps. (2015b). Retrieved from https://www.google.com/maps/d/edit?mid=z9TttLVWPjlY.kAMjYGV4N9jY&hl=en
Google maps. (2015c). Retrieved from https://www.google.com/maps/d/edit?mid=z9TttLVWPjlY.k3_3bUt05Lq4&hl=en
Google maps. (2015d). Retrieved from https://www.google.com/maps/d/edit?mid=z9TttLVWPjlY.kyUiOgdIjjsM&hl=en
Hagentoft, C. (2001). Introduction to building physics. Lund: Studentlitteratur.
Hangan, H. (1999a). Wind-driven rain simulations. Journal of Visualization, 1(4), 337-343.
Hangan, H. (1999b). Wind-driven rain studies. A C-FD-E approach. Journal of Wind Engineering and Industrial Aerodynamics, 81(1-4), 323.
Hens, H. (2010). Wind-driven rain: From theory to reality, in proceedings thermal performance of the exterior envelopes of whole buildings XI. Clearwater, FL.
Hens, H. S. L. C. (2007). Building physics - heat, air and moisture: Fundamentals and engineering methods with examples and exercises. Berlin: Ernst & Sohn.
Högberg, A. B., Kragh, M. K., & van Mook, F. J. (1999). A comparison of driving rain measurements with different gauges. Proceedings of the 5th Symposium of Building Physics in the Nordic Countries, Gothenburg, 361-368.
Hoppestad, S. (1955). Slagregni norge (in Norwegian). Norwegian building research institute, rapport nr. 13, Oslo.
Huang, S., & Li, Q. (2010). Numerical simulations of wind-driven rain on building envelopes based on eulerian multiphase model. Journal of Wind Engineering and Industrial Aerodynamics, 98(12), 843-857.
Hutcheon, N. B., & Handergord G.O.P. (1995). Building science for a cold climate. Canada: IRC.
Júnior, C. M. M., & Carasek, H. (2014). Relationship between the deterioration of multi story buildings facades and the driving rain. Revista De La Construcción, 13(1), 64-73.
Juras, P., Durica, P., & Korenkova, R. (2014). Comparison of different wind-driven rain gauges. Advanced Materials Research, 1057 97-104.
Karagiozis, A. N., Salonvaara, M., Holm, A., & Kuenzel, H. (2003). Influence of wind-driven rain data on hygrothermal performance. Proceedings of the Eighth International IBPSA Conference, Eindhoven, the Netherlands, 627-634.
Karagiozis, A., Hadjisophocleous, G., & Cao, S. (1997). Wind-driven rain distributions on two buildings. Journal of Wind Engineering and Industrial Aerodynamics, 67, 559-572.
Kubilay, A., Derome, D., Blocken, B., & Carmeliet, J. (2014a). High-resolution field measurements of wind-driven rain on an array of low-rise cubic buildings. Building and Environment, 78, 1-13.
Kubilay, A., Derome, D., Blocken, B., & Carmeliet, J. (2014b). High-resolution field measurements of wind-driven rain on an array of low-rise cubic buildings. Building and Environment, 78, 1-13.
Kubilay, A., Derome, D., Blocken, B., & Carmeliet, J. (2014c). Numerical modeling of turbulent dispersion for wind-driven rain on building facades. Environmental Fluid Mechanics, 15(1), 109-133.
Kubilay, A., Derome, D., Blocken, B., & Carmeliet, J. (2013). CFD simulation and validation of wind-driven rain on a building facade with an eulerian multiphase model. Building and Environment, 61, 69-81.
Lacy, R. E. (1965). Driving-rain maps and the onslaught of rain on buildings. RILEM/CIB symp. on moisture problems in buildings, rain penetration, Helsinki,Vol. 3(August 16-19), paper 3-4.
Mohaddes Foroushani, S. S., Ge, H., & Naylor, D. (2014). Effects of roof overhangs on wind-driven rain wetting of a low-rise cubic building: A numerical study. Journal of Wind Engineering and Industrial Aerodynamics, 125, 38-51.
Mook, F. (1998). Measurements of driving rain by a new gauge with wiper. ( No. FAGO 98.62.K).article submitted to Building and Environment.
NBN EN ISO 15927-3 (2009), Hygrothermal performance of buildings-Calculation and presentation of climatic data-Part3: Calculation of a driving rain index for vertical surfaces from hourly wind and rain data.

Nore, K. (May 2006). Measurements of driving rain dispersion on a low-rise test building in Norway. ().Submitted to EIA-Annex 41 meeting, Montreal.
Nore, K., Blocken, B., Petter Jelle, B., Thue, J. V., & Carmeliet, J. (2007). A dataset of wind-driven rain measurements on a low-rise test building in Norway. Building and Environment, 42(5), 2150.
Osorio, M., Ge, H. (April 2013). Report on the errors associated with a wind-driven rain gauge. Concordia University, Montreal, QC, Canada:
Osorio, M., & Ge, H. (April 2013). Error analysis of the wind-driven rain measurements taken on a six-storey building in lower mainland, British Columbia. Unpublished Concordia University,
Pérez-Bella, J. M., Domínguez-Hernández, J., Cano-Suñén, E., Del Coz-Díaz, J. J., & Martín-Rodríguez, Á. (2014). Procedure for a detailed territorial assessment of wind-driven rain and driving-rain wind pressure and its implementation to three Spanish regions. Journal of Wind Engineering and Industrial Aerodynamics, 128, 76-89.
Pérez-Bella, J. M., Domínguez-Hernández, J., Rodríguez-Soria, B., Del Coz-Díaz, J. J., & Cano-Suñén, E. (2012). Estimation of the exposure of buildings to driving rain in Spain from daily wind and rain data. Building and Environment, 57, 259-270.
Pérez-Bella, J. M., Domínguez-Hernández, J., Rodríguez-Soria, B., Del Coz-Díaz, J. J., & Cano-Suñén, E. (2013). Combined use of wind-driven rain and wind pressure to define water penetration risk into building façades: The Spanish case. Building and Environment,
Pérez-Bella, J. M., Domínguez-Hernández, J., Rodríguez-Soria, B., Del Coz-Díaz, J. J., & Cano-Suñén, E. (2013). Optimised method for estimating directional driving rain from synoptic observation data. Journal of Wind Engineering and Industrial Aerodynamics, 113, 1-11.
Rychtáriková, M., & Vargová, A. (2008). Bionics and wind-driven rain on building facades, Slovak journal of civil engineering.Vol. 4, pages 35-40.
Rydock, J. P., Lisø, K. R., Førland, E. J., Nore, K., & Thue, J. V. (2005). A driving rain exposure index for Norway. Building and Environment, 40(11), 1450-1458.
Sahal, N. (2006). Proposed approach for defining climate regions for turkey based on annual driving rain index and heating degree-days for building envelope design. Building and Environment, 41(4), 520-526.
Sauer, P. (1987). An annual driven rain index for china. Building and Environment, 22(4), 239-240.
Straube, J., & Burnett, E. (2000). Simplified prediction of driving rain on buildings. Proceedings of the International Building Physics Conference, 375-382.
Straube, J., & Schumacher, C. (2006). Driving rain loads for Canadian building design.
Tang, W., Davidson, C. I., Finger, S., & Vance, K. (2004). Erosion of limestone building surfaces caused by wind-driven rain: 1. field measurements. Atmospheric Environment, 38(33), 5589-5599.
Van den Brande, T., Blocken, B., & Roels, S. (2013). Rain water runoff from porous building facades: Implementation and application of a first-order runoff model coupled to a HAM model. Building and Environment,
Van Mook, F. J. (1999). Measurements and simulations of driving rain on the main building of the TUE. Proceedings 5th Symposium on Building Physics in the Nordic Countries, 377-384.
Wolf, J., & Griffith, M. (2008). Wind-driven rain as a design parameter. Structures Congress 2008@ sCrossing Borders, 1-7.
Zhu, D. & Fazio, P. (1994). Quantitative studies of driving rain exposure on a vertical building facade in an urban area (M.A.Sc.).
Zhu, D., Mallidi, S. R., & Fazio, P. (1995). Quantitative driving rain exposure on a vertical wall at various Canadian cities. Building and Environment, 30(4), 533-544.
All items in Spectrum are protected by copyright, with all rights reserved. The use of items is governed by Spectrum's terms of access.

Repository Staff Only: item control page

Downloads per month over past year

Research related to the current document (at the CORE website)
- Research related to the current document (at the CORE website)
Back to top Back to top