Strengthening RC T-beams in flexure and shear using new mechanically-anchored FRP and dry fibre systems

Title:

Strengthening RC T-beams in flexure and shear using new mechanically-anchored FRP and dry fibre systems

Mofidi, Amir (2008) Strengthening RC T-beams in flexure and shear using new mechanically-anchored FRP and dry fibre systems. Masters thesis, Concordia University.

[thumbnail of MR40874.pdf]
Preview
Text (application/pdf)
MR40874.pdf - Accepted Version
2MB

Abstract

Current conventional strengthening of reinforced concrete (RC) beams using epoxy-bonded fibre-reinforced polymer (FRP) technique requires difficult surface preparation and is susceptible to a brittle form of failure due to peel-off or debonding of the FRP laminate from the beam. This research presents two new mechanically-anchored FRP and dry fibre strengthening systems that can be used to improve the performance of RC beams in flexure and shear, respectively. Unlike conventional FRP-strengthening methods, the proposed systems require less surface preparation and adhesive application, and eliminate peel-off and debonding of FRP sheets. In order to experimentally evaluate the effectiveness of the new strengthening systems, a total of seven half-scale RC T-beams were tested under four-point loading system up to failure. Three RC T-beams were tested to evaluate the increase in shear capacity using a new FRP strengthening system. One beam was tested as a control beam. One beam was strengthened by using a U-shaped carbon FRP (CFRP) sheet that was externally bonded to the web of the beam. One beam was strengthened by using new anchored U-shaped dry carbon fibre (CF) sheet method. In this method, dry CF sheets are wrapped around and bonded to two steel rods. Then the rods are anchored to the corners of the web-flange intersection of the T-beam with mechanical bolts. The new method relies on utilizing the full mechanical contribution of the dry CF sheets, which will be activated upon development of strain in the RC web, and transferring them through a longitudinal steel rod to the core of the compression web-flange zone by means of mechanical anchors. Four RC T-beams were tested to evaluate the increase in flexural capacity and ductility using a new FRP strengthening system. One beam was tested as a control beam. One beam was strengthened with conventional epoxy-bonding method. Two beams were strengthened with the new hybrid FRP sheet / ductile anchor system (one with unbonded CFRP, while the other with bonded CFRP). The proposed system leads to a ductile failure mode by triggering the yield in the steel anchor system (steel links) while avoiding peel- off or debonding of FRP sheets, which is sudden in nature. The tested beams where modeled to analytically evaluate their performance. The experimental and analytical results indicate that the proposed new retrofitting methods are structurally efficient in enhancing the shear and flexure strengths and ductility of RC T-beams compared to conventional epoxy-bonding methods

Divisions:Concordia University > Gina Cody School of Engineering and Computer Science > Building, Civil and Environmental Engineering
Item Type:Thesis (Masters)
Authors:Mofidi, Amir
Pagination:xx, 140 leaves : ill. ; 29 cm.
Institution:Concordia University
Degree Name:M.A. Sc.
Program:Building, Civil and Environmental Engineering
Date:2008
Thesis Supervisor(s):Galal, Khaled
Identification Number:LE 3 C66B85M 2008 M64
ID Code:975858
Deposited By: Concordia University Library
Deposited On:22 Jan 2013 16:16
Last Modified:13 Jul 2020 20:08
Related URLs:
All items in Spectrum are protected by copyright, with all rights reserved. The use of items is governed by Spectrum's terms of access.

Repository Staff Only: item control page

Downloads per month over past year

Research related to the current document (at the CORE website)
- Research related to the current document (at the CORE website)
Back to top Back to top