Login | Register

Comparison of Wind Tunnel Measurements with NBCC 2010 Wind-Induced Torsion Provisions for Low- and Medium-Rise Buildings

Title:

Comparison of Wind Tunnel Measurements with NBCC 2010 Wind-Induced Torsion Provisions for Low- and Medium-Rise Buildings

Elsharawy, M., Galal, K. and Stathopoulos, T. (2014) Comparison of Wind Tunnel Measurements with NBCC 2010 Wind-Induced Torsion Provisions for Low- and Medium-Rise Buildings. Canadian Journal of Civil Engineering, 41 (5). pp. 409-420.

[thumbnail of 2014 Comparison of Wind Tunnel Measurements with NBCC 2010 Wind-Induced Torsion Provisions for Low- and Medium-Rise Buildings.pdf]
Preview
Text (application/pdf)
2014 Comparison of Wind Tunnel Measurements with NBCC 2010 Wind-Induced Torsion Provisions for Low- and Medium-Rise Buildings.pdf
1MB

Official URL: http://dx.doi.org/10.1139/cjce-2013-0239

Abstract

The aim of this study is to assess wind-induced torsional loads on low- and medium-rise buildings determined in accordance with the National Building Code of Canada (NBCC 2010). Two building models with the same horizontal dimensions but different gabled-roof angles (0° and 45°) were tested at different full-scale equivalent eave heights (6, 12, 20, 30, 40, 50, and 60 m) in open terrain exposure for several wind directions (every 15°). Wind-induced measured pressures were numerically integrated over all building surfaces and results were obtained for along-wind force, across-wind force, and torsional moment. Torsion load case (i.e., maximum torsion and corresponding shear) and shear load case (i.e., maximum shear and corresponding torsion) were evaluated to reflect the maximum actual wind load effects in the two horizontal directions (i.e., transverse and longitudinal). The evaluated torsion and shear load cases were also compared with the current torsion- and shear-related provisions in the NBCC 2010. The results demonstrated significant discrepancies between NBCC 2010 and the wind tunnel measurements regarding the evaluation of torsional wind loads on low- and medium-rise buildings. Finally, shear and torsion load cases were suggested for evaluating wind loads in the design of low- and medium-rise rectangular buildings.

Divisions:Concordia University > Gina Cody School of Engineering and Computer Science > Building, Civil and Environmental Engineering
Item Type:Article
Refereed:Yes
Authors:Elsharawy, M. and Galal, K. and Stathopoulos, T.
Journal or Publication:Canadian Journal of Civil Engineering
Date:2014
Digital Object Identifier (DOI):10.1139/cjce-2013-0239
ID Code:981660
Deposited By: Theodore Stathopoulos
Deposited On:26 Sep 2016 14:31
Last Modified:18 Jan 2018 17:53
All items in Spectrum are protected by copyright, with all rights reserved. The use of items is governed by Spectrum's terms of access.

Repository Staff Only: item control page

Downloads per month over past year

Research related to the current document (at the CORE website)
- Research related to the current document (at the CORE website)
Back to top Back to top