Sadiq, Zubi, Al-Kassawneh, Muna, Safiabadi Tali, Seyed Hamid and Jahanshahi-Anbuhi, Sana (2025) Dextran-Gold Nanoparticle-Based Tablets and Swabs for Colorimetric Detection of Urinary H2O2. ACS Applied Nano Materials, 8 (2). pp. 1008-1020. ISSN 2574-0970
Preview |
Text (Accepted manuscript version) (application/pdf)
9MBproof.pdf - Accepted Version Available under License Spectrum Terms of Access. |
Preview |
Image (application/pdf)
1MBan4c05691_si_001.pdf - Supplemental Material Available under License Spectrum Terms of Access. |
Official URL: https://doi.org/10.1021/acsanm.4c05691
Abstract
Diagnosis of oxidative stress is essential to avoiding serious life-threatening situations. Hydrogen peroxide (H2O2) is a potential biomarker of oxidative stress. Herein, we introduce a reagent-free, nanoscale approach for the colorimetric detection of urinary H2O2 utilizing dextran-gold nanoparticles (dAuNPs). The plasmonic properties of these nanoparticles are central to their function, leveraging their high surface area and tunable optical characteristics for sensitive detection. We transformed the colloidal dAuNPs solution into two formats: as a tablet (dAuNPs-Tablet) or impregnated on a cotton swab (dAuNPs-Swab). The assay generates hydroxyl radicle (•OH) from H2O2 via the Fenton reaction, followed by nanoscale-driven detection of H2O2 using a plasmonic tablet and swab sensors. In the presence of H2O2 in a sample, the red color of the tablet solution or plasmonic swab turns to blue color due to salt-induced nanoparticles aggregation. The transition in color is observed due to •OH-assisted degradation of the dextran layer around dAuNPs, leading to the loss of colloidal stability and subsequent aggregation of dAuNPs. Sodium chloride acts as the aggregating agent, enhancing the nanoscale interactions. The detection limit in artificial urine is found to be 50 µM for the tablet sensor and 100 µM for the swab sensor. The plasmonic tablet is more stable as compared to a plasmonic swab which gradually loses stability, after one month, with approximately 40% degradation within three months. Interference studies demonstrate the high selectivity of both platforms for H2O2 detection. Notably, we investigated the H2O2 levels in human urine samples from healthy volunteers (both female and male) before and after green tea consumption. The observed decrease in H2O2 level in urine post-green tea consumption suggests a potential role of green tea antioxidants in mitigating oxidative stress. The utilization of nanoprobes in our research not only enhances our understanding of oxidative stress dynamics but also drives advancements in point-of-care detection platforms, offering enhanced portability and ease of use of nanoprobes. These platforms open exciting avenues in healthcare diagnosis.
Divisions: | Concordia University > Gina Cody School of Engineering and Computer Science > Chemical and Materials Engineering |
---|---|
Item Type: | Article |
Refereed: | Yes |
Authors: | Sadiq, Zubi and Al-Kassawneh, Muna and Safiabadi Tali, Seyed Hamid and Jahanshahi-Anbuhi, Sana |
Journal or Publication: | ACS Applied Nano Materials |
Date: | 8 January 2025 |
Funders: |
|
Digital Object Identifier (DOI): | 10.1021/acsanm.4c05691 |
ID Code: | 995045 |
Deposited By: | Zubi Sadiq |
Deposited On: | 04 Feb 2025 20:37 |
Last Modified: | 04 Feb 2025 21:08 |
Repository Staff Only: item control page