Login | Register

Modelling and evaluation of the performance of building-integrated open loop air-based photovoltaic/thermal systems

Title:

Modelling and evaluation of the performance of building-integrated open loop air-based photovoltaic/thermal systems

Candanedo Ibarra, Luis Miguel (2010) Modelling and evaluation of the performance of building-integrated open loop air-based photovoltaic/thermal systems. PhD thesis, Concordia University.

[thumbnail of NR71143.pdf]
Preview
Text (application/pdf)
NR71143.pdf - Accepted Version
8MB

Abstract

Building-Integrated Photovoltaic/Thermal Systems (BIPV/T) systems are photovoltaic installations incorporated as the exterior layer of the building envelope with the additional function of recovering thermal energy, which can then be used for space heating, domestic water heating and possibly for cooling. Some advantages of a BIPV/T system over an autonomous PV array include lower installation costs due to the replacement of cladding material, elimination of extra support structures and reduced electrical transmission losses. In addition, recovering the heat from the photovoltaic panels cools them and thus improves their electrical efficiency. Due to the novelty of BIPV/T systems, there is a need for the measurement of convective heat transfer coefficients and development of correlations for their prediction. The development of an integrated energy model, including correlations for the prediction of convective heat transfer coefficients in BIPV/T systems was one of the main objectives of this thesis. Accurate measurements of convective heat transfer coefficients have been carried out for two open loop BIPV/T configurations: smooth and ribbed. The BIPV/T systems were tested at 30°-45° tilt angles and had a length/hydraulic diameter ratio of 38 which is representative of roof applications. It was found that for the BIPV/T ribbed case, the calculated Nusselt numbers are on average 2.6 times higher than the Nusselt numbers predicted by the Dittus-Boelter correlation. Pressure drop measurements were performed for the two configurations and the results are presented in terms of the Darcy friction factors and compared to the Blasius equation. For both cases, the friction factors are higher compared to the ones predicted by the Blasius equation. Previous existing electrical photovoltaic models have been used to couple their features to the lumped parameter thermal network modelling approach used in this thesis. Two thermal network models, steady state and transient, have been developed in this work and validated against experimental data. The steady state model is useful for a quick evaluation of the thermal/electrical performance, while the transient model gives a more accurate representation of the system by considering the thermal storage capacity of the materials. Finally, conclusions and general recommendations and guidelines for the design and construction of BIVP/T systems are provided

Divisions:Concordia University > Gina Cody School of Engineering and Computer Science > Building, Civil and Environmental Engineering
Item Type:Thesis (PhD)
Authors:Candanedo Ibarra, Luis Miguel
Pagination:xviii, 212 leaves : ill. (some col.) ; 29 cm.
Institution:Concordia University
Degree Name:Ph. D.
Program:Building, Civil and Environmental Engineering
Date:2010
Thesis Supervisor(s):Athienitis, Andreas
Identification Number:LE 3 C66B85P 2010 C36
ID Code:979429
Deposited By: Concordia University Library
Deposited On:09 Dec 2014 17:59
Last Modified:13 Jul 2020 20:12
Related URLs:
All items in Spectrum are protected by copyright, with all rights reserved. The use of items is governed by Spectrum's terms of access.

Repository Staff Only: item control page

Downloads per month over past year

Research related to the current document (at the CORE website)
- Research related to the current document (at the CORE website)
Back to top Back to top